System 150 Installation Advice

Clip-In Tiles, Concealed Grid

Notes

Maximum suspension centres should only be considered for lightweight* installations.

Emac hangers should be installed a maximum of 300mm from the end of a run of Emac channel and 300mm from the joint between these channels. Where two omega bars meet and are spliced together, an Emac channel should be installed within 500mm.

It is considered good practice to stagger joints in supporting structures.

 

 

Additional Loads

When supporting services such as downlights, speakers, detectors and other mechanical and electrical services, the maximum load applied to the ceiling tile must not exceed 2.5kg including spreader yokes if applicable. The SAS pattress system allows the integration of heavier items by distributing the load back to the Emac Omega Bar. The pattress can accommodate a load of up to 6kg and are available in sizes to suit all standard modules. For load greater than 6kg we recommend independent suspension. Pattress's are available in sizes to suit all standard modules.

*"Lightweight" meaning base system only such as fleece or pad backing. Where the ceiling supports the load of services or for acoustically upgraded ceilings the suspension should be installed to minimum dimensions shown above. Suspension centres should always be considered when applying additional loads.


For further advice please contact the SAS technical department.

 

 

System 150 Isometric Drawing Thumb




150 Image 01 Thumb

award sponsor

bco-logo2013 (170 x 170)
Pleased to be sponsoring
'Fit out of Workplace' award

world-class interiors

corporate (170 x 104)
Watch our new corporate video or download a copy of the brochure.

find us on

Tweet (30 x 30) linkedin (30 x 30) Fb (30 x 30) youtube (30 x 30) plus-badge

career opportunites

Current career opportunities within SAS

register for updates

Please enter your email address below to register for updates